Sale
Evaporator for Ores
ADP-512 High Heat Evaporator for Ores for Karl Fischer

[Features]
1) Measurement for micro amount of water is least affected from ambient moisture because the movement of
sample boat is controlled by magnet, operated outside the sealed heating unit, and thus accurate and reliable
results are assured.
2) The newly designed electric furnace operates in a wide range of degrees from room temperature up to 1000°C,
featuring relatively short warm-up time, taking approximately 30 minutes for temperature rise as well as for
equilibrium respectively.
3) PID control by the built-in thermostat provides an accurate and stable oven temperature.
4) The safety while working on the electric oven is secured because the maximum temperature over the oven
surface is always kept under 70°C.
5) The built-in excessive heat prevention unit is another safety measures with a thermometer in it, which is
separate from the sensor for temperature control.
6) This evaporator is equipped with two types of electric furnace (for low temperature and for high temperature),
which enables measurement for hygroscopic water as well as combined water without taking the sample out
of the oven.
24,000.00 24000.0 USD
Sale
KCHD-502H Multiple Sample Changer w/Heat Option
KCHD-502H Multiple Sample Changer with heater option
19,000.00 19000.0 USD
Sale
KDCU-551H Auto Cleaning and Sampling Unit
KDCU-551H Auto Cleaning and Sampling Unit
16,271.00 16271.0 USD
Sale
Abbe Multi-Wavelength Refractometer model 1410 DR-M2
Abbe Multi-Wavelength Refractometer model 1410 DR-M2 Refractive index or Abbe number can be measured at different wavelengths ranging from 450 to 1,100nm. For measurement at wavelengths ranging from 681 to 1,100nm, the optional Near Infrared Ray Viewer (parts no. RE-9118) is required. The DR-M2 dgitally displays measurement result of refractive index or Abbe number digitally on the LCD. Measurement can be acheived by matching the boundary line at the intersection point of the cross haires. MEASUREMENT RANGE: @wavelength 450nm: (nD) 1.3277 to 1.7379 @wavelength 589nm: (nD) 1.3000 to 1.7100 @wavelength 680nm: (nD) 1.2912 to 1.7011 @wavelength 1,100nm: (nD) 1,2764 to 1.6843 MINIMUM INDICATION: 0.0001 refractive index; 0.1 Abbe number MEASUREMENT ACCURACY: +-0.0002 in refractive index WAVELENGTH RANGE: from 450 to 1,100nm (with interface filters) MEASUREMENT TEMP RANGE: 5 to 50degrees C POWER SUPPLY: AC100 to 240V, 50/60Hz DIMENSION AND WEIGHT: Refractometer 13x29x31cm, 6.0kg; Light source unit 15x33x11cm, 3.0kg
15,750.00 15750.0 USD
Sale
For Metal cleaning acid & ferrous concentrations
DCM-101
15,625.00 15625.0 USD
Sale
Automatic Digital Refractometer RX-9000a
ARX-9000a:Automatic Digital Refractometer RX-9000a Model: RX-9000a Cat.No. 3263 Measurement Range Refractive index (nD) 1.32500 to 1.70000 Brix 0.00 to 100.00% (ATC : 5 to 70°C) Minimum Indication Refractive index (nD):0.00001 or 0.0001 (by selection) Brix 0.01% or 0.1% (by selection) Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 (nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C ) Refractive index (nD) : ±0.00010 (For ranges other than the above) Brix±0.03% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C Brix±0.05% (Brix 50.01 to 95.00% at Measurement Temperature 10.00 to 30.00°C Brix±0.10% (For ranges other than the above, with Sucrose solution by MODE1) Repeatability Refractive index (nD) : ±0.00002 (nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C ) Refractive index (nD) : ±0.00005 (For ranges other than the above) Brix±0.01% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C Brix±0.02% (For ranges other than the above, with Sucrose solution by MODE1) Measurement Temperature: 5 to 70°C Mode: 3 types Power Supply: AC100V to 240V, 50/60Hz Power consumption: 480VA Dimensions & weight: 37x26x14cm, 9.0kg (main unit only) Output terminals: Printer (for ATAGO digital printers and RS-232C)
14,500.00 14500.0 USD
Sale
KCHD-502N Multiple Sample Changer
KCHD-502N Multiple Sample Changer

Features
• Adoption of a peristaltic pump allows an operator to measure the density on higher viscous sample of 30,000 mPa•s
• The sequential program automatically stops when the unit detects an empty vial position after the last sample vial is finished.
• This unit is equipped with self-diagnostic function by checking sequence program, keypad function, and display.
• The auto-power-off functions when a series of measurements is finished so that it saves electricity when operated overnight unattended. This feature can be set in while the unit is being activated.
• The cleaning efficiency is increased by blending air into rinse solvent. By this way, the total amount of rinse solvent is decreased and saved. In addition, not only inside but outside of the nozzle can be cleaned very well since the rinse solution is fed from the outside of the nozzle unit.
• Expensive sample materials like perfume or fragrance can be returned back to sample vial after measurement are over.
• The CHD-502 series provides a variety of models with different specifications depending on what type of sample material is going to be measured : N type for room temperature used, SS type for small size sampling, H type for high temperature or C type for low temperature used.

Type name: Standard type N
Number of vials: Up to 30 (20mL vial)
Min. sample required: 10mL
Sample position: Turntable System
Sampling method: Pressurizing by peristaltic pump
Drain system: 1) Pressurized draining 2) Sample-returning to vial system
Program sequence: 1) Sample measurement only 2) Sample measurement after the "Air & Water" calibration 3) Sample measurement after the "Two kinds of Standard liquids" calibration
Control: 1) Auto-start by [Meas.] key of density / specific gravity meter or concentration meter 2) Auto-start by [Start.] key of CHD-502 unit 3) Rinsing and purging 4) Auto-calibration by [Calib.] key of density / specific gravity meter or concentration meter 5) Priority measurement
Display: 20 digits by 2 lines LCD with a backlight
Ext. communications: 1) Simplified serial interface via the connecting cable (980303388) 2) RS-232C interface for communications
Ambient condition: 1) Temperature: 5 ~ 35°C ; 2) Humidity: less than 85%RH (No condensation)
Dimension: 582(W) x 445(D) x 392(H) mm
Weight: Approx. 17kg
14,200.00 14200.0 USD
Sale
Density/Specific Gravity Meter
ASTM D1250,D1475,D4052,D4806,D5002,D5798,D5931

Quickest measurement in 20 seconds Minimum sample of 1.0 mL
Viscosity correction for high-viscosity samples*1 Touchscreen operation
Comes with Density Standard Liquid Equipped with sampling*2 & dry pump Completely ready for use Customizable display & sound
Easy operation & maintenance-free

-Measurement Range; 0 ~ 3 g/cm3
-Temperature Range; 0 ~ 96°C (32 ~ 204.8°F)
-Accuracy; Density ±1x10-4 g/cm3 (0.0001 g/cm3)/ temperature ±0.05 °C (±0.09 °F)
-Repeatability; SD 5x10-5 g/cm3
-Min sample required; Approx. 1 mL (Syringe) / Approx. 2mL (Pump)
-Measurement time; to 4 mins (Manual) / 2 to 10 mins (Auto)
-Resolution; Density & SG 0.0001/ temperature 0.01
-Viscosity Correction: YES
-Method; Saves up to 100 different methods in built-in memory
-Data I/O; USB flash drive as data storage medium, app notes provided in USB flash drive
-Dimensions; 320 (W) x 365 (D) x 250 (H) mm (12.6 (W) x 14.4 (D) x 9.8 (H) inches)
-Weight; 18 kg (39.7 lbs)
13,900.00 13900.0 USD
Sale
Abbe Refractometer model 1217 NAR-1T-Lo
Abbe Refractometer model 1217 NAR-1T-Lo -Abbe Refractometer for low refractive index measurement -Refractive Index -Ranges: 1.1500 to 1.4800 nD -Resolution: 0.001 nD -Measurement range: 5 to 50degrees C -Built in light source, digital thermometer, nozzles for connecting a constant temperature waterbath
12,000.00 12000.0 USD
Sale
Automatic Digital Refractometer RX-5000i
ARX-5000i:Automatic Digital Refractometer RX-5000i Model RX-5000i Cat.No. 3276 Measurement Range: Refractive index (nD) : 1.32422 to 1.58000 Brix : 0.00 to 100.00% ( 5 to 75°C ATC) Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature ± 0.05°C Repeatability Refractive index (nD) : ±0.00002 Brix : ±0.01% Power Supply to 240V, 50/60Hz Weight 6.6kg (Main Unit only) Features include: -Internal Peltier Thermomodule; Measure at YOUR chosen temperature with NO waterbatch! -Touch Screen Interface; Simple, easy-to-use, and customizable -History Function; Automatically remembers the last 30 measurements -Programmable User Scale; Enter up to 98 of your own user scales for convenient, chart-free measurements -Password System; Maintain internal and external security -Simple, Fast Operation; Begin measuring in minutes of taking it out of the box -Versatile Connections; Hook up to a printer, or to MS Windows via USB -Compact design; Saves on important bench top space
11,300.00 11300.0 USD
Sale
Evaporator (KF-610 series)
ADP-611 Evaporator

The ADP-611 is an evaporator/oven to be used and connected with a KF moisture titrator for moisture testing of solid samples, powder samples or samples that may interfere by side reaction if titrated by direct injection method.

SPECIFICATIONS:
-Type and model; Model ADP-611 Evaporator
-Heating method; Electrically conductive clear heater glass
-Temperature range; Control method: proportional
Setting range: 50 ~ 300°C Minimum temperature setting: 1°C
Temperature precision: ± 2°C
Temperature sensor: K-thermocouple
-Temperature display: LED digital 3 characters
-Heater unit : Pyrex glass tube φ 30 × 335mm
-Sample boat: Pyrex glass 68 L × 25 W × 15 H mm , Capacity 16mL
-Carrier gas: Nitrogen: not included in supplied parts./ Nitrogen gas, regulator, and tubing have to be prepared by user
-Gas dryer: Zeolite 100g 2 pcs
-Gas flow: 100 ~ 300 mL/min
-Dimension: 370 (W) × 195 (D) × 217 (H) mm
-Power: AC100 ~ 120V± 10% 50Hz/60Hz / AC220 ~ 240V± 10% 50Hz/60Hz (Pre-adjusted before shipment from the factory)
-Power Consumption: Approx. 300W
Weight: Approx. 5kg
11,299.00 11299.0 USD
Sale
Low Heat Flow/Embedding Type
KTC-C: Low Heat Flow/Embedding Type
11,111.11 11111.11 USD
Sale
Low Heat Flow/Embedding Type
KTC-B: Low Heat Flow/Embedding Type
11,111.11 11111.11 USD
Sale
Automatic Digital Refractometer RX-7000a
ARX-7000a:Automatic Digital Refractometer RX-7000a Model RX-7000α Cat.No. 3262 Measurement Range Refractive index (nD) 1.3250 to 1.7000 Brix 0.00 to 100.0% (ATC : 5 to 70°C) Minimum Indication 0.0001or 0.00001(by selection) Brix 0.1% or 0.01% (by selection) Temperature: 0.01°C Measurement Accuracy Refractive index (nD) ±0.0001 Brix ±0.1% Measurement Temperature 5 to 70°C Repeatability Refractive index : ±0.00005 Brix : ±0.02% Mode 3 types Power Supply AC100V to 240V, 50/60Hz Power consumption 480VA Dimensions & weight 37×26×14cm, 9.0kg (Main Unit only) Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-RX : Cat.No.3121 • Digital Printer DP-RD : Cat.No.3122 • Digital Printer DP-62α : Cat.No.3019 • Volatile sample adapter : RE-56152 • Flow cell attachment : RE-56155 • 10% Sucrose (±0.01%) : RE-111001 • 30% Sucrose (±0.01%) : RE-113001 • 50% Sucrose (±0.02%) : RE-115002 Parts • Cover plate : RE-6532 • Printer paper (regular) for DP-RX : RE-8412 • Printer paper (long-term storage)for DP-RX : RE-8414 • Fan Filter Replacement : RE-58001
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-5000a-Bev
ARX-5000a-Bev:Automatic Digital Refractometer RX-5000a-Bev Model RX-5000α-Bev Cat.No. 3271 Measurement Range Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.00 to 100.00% ( 5 to 60°C ATC) Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature 5 to 60°C Repeatability Refractive index : ±0.00002 Brix : ±0.01% Mode 3 types Power Supply AC100V to 240V, 50/60Hz Power consumption 480VA Dimensions & weight 37×26×14cm, 9.0kg (Main Unit only) Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital printer DP-RX : Cat.No.3121 • Digital printer DP-RD : Cat.No.3122 Parts • Cover plate : RE-56156 • Printer paper (regular) for DP-RX : RE-8412 • Printer paper (long-term storage)for DP-RX : RE-8414 • Fan Filter Replacement : RE-58001
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-5000a
ARX-5000a:Automatic Digital Refractometer RX-5000a Model RX-5000α Cat.No. 3261 Measurement Range: Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.00 to 100.00% ( 5 to 60°C ATC) Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature 5 to 60°C Repeatability Refractive index : ±0.00002 Brix : ±0.01% Power Supply to 240V, 50/60Hz Mode 3 types Dimensions & weight 37×26×14cm, 9.0kg (Main Unit only) Power consumption 480VA Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-RX : Cat.No.3121 • Digital Printer DP-RD : Cat.No.3122 • Digital printer DP-62α : Cat.No.3019 • Volatile sample adapter for RX-5000α : RE-56151 • Flow cell attachment :RE-56156 • 10% Sucrose (±0.01%) : RE-111001 • 30% Sucrose (±0.01%) : RE-113001 • 50% Sucrose (±0.02%) : RE-115002
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-007a
ARX-007a:Automatic Digital Refractometer RX-007a Model RX-007α Cat.No. 3921 Measurement Range Brix 0.000 to 5.000% Refractive index (RI):1.330150 to 1.341500 Minimum Indication Brix 0.001% Refractive index (RI) 0.000001 Temperature 0.01°C Measurement Accuracy Brix±0.005% Refractive index (RI):±0.000010 (at 20°C) (under specified ambient temperature and constant temperature) Dimensions & Weight 37×26×14cm, 6.9kg (Main Unit only) Measurement Temperature 15.00 to 30.00°C Mode 2 types Power Supply AC100V to 240V, 50/60Hz Power consumption 480VA Output Terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-RX : Cat.No.3121 • Digital Printer DP-RD : Cat.No.3122 Parts • Printer paper (regular) for DP-RX : RE-8412 • Printer paper (long-term storage)for DP-RX : RE-8414 • Fan Filter Replacement : RE-58001
11,000.00 11000.0 USD
Sale
KDCU-551N Auto Cleaning and Sampling Unit
KDCU-551N Auto Cleaning and Sampling Unit
10,847.00 10847.0 USD
Sale
Refractometer
RA-620 Benchtop Refractometer

Specs:

-Measuring Method: Detection of Critical Angle of Optical Refraction
-Light Source: LED Na-D Line (589.3nm)
-Measuring Range: Refractive Index (nD)=1.3200 ~ 1.58000,
Brix=0.00 ~ 100.00%
-Accuracy *1:Refractive Index (nD)=±0.00002,Brix=±0.014%(0~85%)
-Repeatability *2:Refractive Index (nD)=±0.00001,Brix=±0.01%
-Resolution:Refractive Index (nD)=0.00001,Brix=0.01%
-Temperature Control:Peltier Thermostat 5 ~ 75°C *3
-Temperature Indication Resolution:0.01°C
-Minimum Amount of Sample: 0.2mL
-Display:4.7-inch Backlit Colour LCD
-Operation:Touch Screen
-Security:Password Protection
-Data Storage: # of methods=100,Measurement results=up to 300, calibration record=up to 20,Check Record=up to 20, External Storage=USB Flash Drive
-Temperature Compensation: Brix=5.00 75.00 (Automatic compensation by preprogrammed conversion table.)
-Interfaces: LAN, USB1.1,RS-232
-Power Supply:AC 100~240 V, 50/60 Hz (AC adapter supplied with instrument.)
-Dimensions:191(W)×281(D)×161(H)mm
-Weight:5Kg
10,550.00 10550.0 USD
Sale
KEM Sample Changer, 12 Samples
KCHG-310-12: KEM Sample Changer, 12 Samples
10,150.00 10150.0 USD