Sale
KEM Sample Changer, 12 Samples
KCHG-310-12: KEM Sample Changer, 12 Samples
10,150.00 10150.0 USD
Sale
11 Position Sample Changer
CHA-700-11 : Automatic Titrator Multiple Sample Changer (11 sample)
9,900.00 9900.0 USD
Sale
KEM Particle Analyzer
PCD-500
8,820.00 8820.0 USD
Sale
6 Position Sample Changer
CHA-700 : Automatic Titrator Multiple Sample Changer
8,500.00 8500.0 USD
Sale
Automatic Titrator (with standard preamp)
KEM AT­-710B Automatic Potentiometric Titrator with Standard Preamp.

Specifications
­Type: Automatic Potentiometric Titrator

­Model: AT­710B

­Product configuration: AT­710 w/standard preamp, w/Magnetic stirrer
(combined pH electrode and temperature compensation electrode included)

­Detection range:
1) Potentiometric : ­2000mV to +2000mV
2) pH : ­20.000 to 20.00pH
3) Temperature : 0 to 100°C

­Titration mode: Auto Titration, Auto Intermit, Intermit, Stat
­Method: Standard method 20. (Max 2 methods can be linked)

­Kinds of titration: Potentiometric (acid/base, redox, precipitation), Photometric,
Polarization, Conductivity

­Titration form: Full titration (Auto EP detection), EP Stop, Level Stop

­Special application: Measurement of electrode potential (pH, potential), Acid
dissociation constant (pKa)

­Key operation: Sheet Key on the main unit

­Displays:
1) White LED­backlit LCD
2) English / Japanese / Mandarin Chinese /Korean / Russian / Spanish
3) 1­channel display

­Calculation: Concentration of content, statistics data processing (mean, SD
and RSD) and automatic averaging of blank and factor value

­Data Storage: 50 samples

­GLP conformance: Registration of operator / Record of check results / Record
of electrode calibration / Verification of burette capacity / Management of
conduction time

­Burette size: 20mL glass burette with brown cover (Standard) Optional burette
units: 10mL, 5mL, or 1mL

­Burette accuracy:
50mL burette(Auto dispenser) ± 0.5mL,
20mL burette ± 0.02mL reproducibility ± 0.01mL
10mL burette ± 0.015mL reproducibility ± 0.005mL
5mL burette ± 0.01mL reproducibility ± 0.003mL
1mL burette ± 0.005mL ; reproducibility ± 0.001mL

­External I/O:
RS­232 port x 2: for Dot matrix printer, Electronic balance, Data Capture
Software (SOFT­CAP)
SS­BUS × 1: for Multiple sample changer, APB
ELE. × 1: for Smart electrode
TEMP.COMP. × 1: an Input terminal for the temperature sensor to correct reagent
volume, sensor Pt100, temperature reading accuracy: ±0.5°C (burette 1 only)
USB × 1: for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot
switch, USB HUB, Android device

­Extensibility:
Automatic piston burette: Can control max 10 burette drives (Including two
built­in burette drives)
Multiple sample changer: CHA­700 series

­Ambient condition:

1) Temperature: 5 to 35°C
2) Humidity: 85%RH or below (no condensation)

­Power source: AC100 ­ 240V ±10% 50/60 Hz
­Power consumption: 20W

­Dimensions:
Titration unit: 141(W) × 296(D) × 367(H)mm
Printer: 106(W) × 180(D) × 88(H) mm

­Weight:
Titration unit: Approx. 4.0kg
Printer : Approx. 0.4kg

­Conformity standard: CE marking EMC: EN61326­1 LVD: EN61010­1 RE
Directive Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01
8,500.00 8500.0 USD
Sale
HI902C Potentiometric Titrator
HI902C-01Z:The HI 902C is an automatic titrator that complements a wide range of laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations. The HI 902C dispenses the titrant, detects the endpoint and performs all necessary calculations automatically. This versatile titrator supports up to 100 methods, standard or user defined. When powered on, the instrument initiates an internal diagnostics check and then readies itself for the first titration of the day. A large color LCD screen clearly shows the chosen method and related information. A real-time titration curve can be shown on the display; this feature is useful when new methods are tested or when a procedure needs to be optimized. At the end of the titration, all data, including the graph, are automatically stored in memory and can be copied via the built-in USB drive or through direct connection with a PC. This titrator is supplied with a pack of standard methods or you can create your own. Methods (standard and user) can be upgraded, stored or deleted by connecting the titrator to a PC with HANNA software or USB flash drive. Software updates can also be performed using a USB flash drive. Users can connect pH, ORP or ISE electrodes to the HI 902C, as well as create a complete workstation with a PC, monitor, keyboard and printer. The HI 902C complies with GLP specifications. All GLP information from each sample can be stored, including ID number, date and time of analysis, electrode ID code, and last calibration date. SPECIFICATIONS Range: mV,-2000.0 to 2000.0mV Range: pH,-2.000 to 20.000pH Range: ISE, 1 x 10-6 to 9.99 x 1010 Range: Temperature, -5.0 to 105.0°C/23 to 221°F/268.2 to 378.2 K Resolution: mV, 0.1mV Resolution: pH,0.1/0.01/0.001pH Resolution: ISE,1, 0.1,0.01 Resoultion: Temperature, 0.1°C/0.1°F/0.1K Accurracy: mV, ±0.1 mV Accuracy: pH, ±0.001 pH Accuracy: ±0.5% monovalent;±1% divalent Accuracy: ±0.1°C/±0.2°F/±0.1K Burette Sizes; 5, 10, and 25 mL Burette Resolution; 1/40000 Display Resolution; 0.001 mL Dosing Accuracy; ±0.1% of full burette volume Display; 5.7” (320 x 240 pixel) backlit color LCD Languages; English, Portuguese, Spanish Methods; load up to 100 methods (standard and user-defined) Burette Auto-Detection; burette size is automatically recognized when inserted into the unit Programmable Stirrer; propeller type, 100-2500 RPM, automatically held within 10% of the set value, resolution 100 rpm Flow Rate; user-selectable from 0.1 mL/min to 2 x burette volumes/min Temperature Compensation; manual or automatic (ATC) End-Point Detection; equivalence point (1st or 2nd derivative) or fixed pH/mV value Potentiometric titrations; acid-base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric, back titrations and titre determination Realtime and Stored Graphs; mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve, in pH-mode, mV-mode or ISE mode: pH/mV/concentration values versus time-datalogging results Data Storage; up to 100 titration and pH/mV/ISE reports USB Host (side); flash drive compatibility for transfers of methods and reports Peripherals (rear); connections for VGA display, PS/2 keyboard, parallel printer, USB device input, RS232, interface for future expansion GLP Conformity; instrumentation data storage and printing capabilities Dimensions; 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in) Weight; approximately 10 kg (22 lbs.) with one pump and stirrer assembly
6,700.00 6700.0 USD
Sale
Automatic Piston Burette
APB-620; Automatic Piston Burette for Auto Titrator
5,152.00 5152.0 USD
Sale
Specific Conductivity Meter (for ultra-purified water)
KCM-117S: Specific Conductivity Meter (for ultra-purified water)
4,924.14 4924.14 USD
Sale
Automatic Piston Burette
APB-610; Automatic Piston Burette for Auto Titrator
4,745.00 4745.0 USD
Sale
Photometric Preamp. Adaptor
KPTA-610: Photometric Preamp. Adaptor
4,166.67 4166.67 USD
Sale
Photometric Preamp. Adaptor (530nm 1 pc)
KPTA-510: Photometric Preamp. Adaptor
4,166.67 4166.67 USD
Sale
Automatick Piston Burette for Volumetri Titration
APB-600-KF
4,067.00 4067.0 USD
Sale
Automatic Piston Burette
APB-600-AT
4,067.00 4067.0 USD
Sale
Photometric Sensor
K12-00110-00:Photometric Sensor
3,788.00 3788.0 USD
Sale
Specific Conductivity Meter
KCM-117: Specific Conductivity Meter
3,785.00 3785.0 USD
Sale
2-system Pump A (for shower & rinse)
K12-02854 (old part no. K020-0006:2-system Pump A (for shower & rinse). Stronger shower rinse for non-aqueous samples.
3,555.00 3555.0 USD
Sale
Conductivity Preamp
KCMT-610: Conductivity Preamp
3,472.22 3472.2200000000003 USD
Sale
Conductivity Preamp
KCMT-510: Conductivity Preamp
3,472.22 3472.2200000000003 USD
Sale
2Component Type Titration Cell Unit with Cock
K1207356 (K12-006-6300-48); Titration Cell Unit, 2 solution with drain valve. The Cell Unit includes all of the necessary "glassware" items including: -Titration Cell with drain valve; -Inner buret (2 solution); K433-0006 -Detector electrode; K103-M713 -Port plug 19/25; K550-0073 -Desiccant tube; K433-3116 -Stirrer bar; K500-3362S
3,428.00 3428.0 USD
Sale
2-system Pump B (for separate drain)
K020-0007:2-system Pump B (for separate drain)
3,345.52 3345.52 USD