Sale
Aquapal III Moisture Analyzer w/ Standard Glassware
Aquapal III Moisture Analyzer W/ Standard Glassware:
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved Manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm -% - ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
7,850.00 7850.0 USD
Sale
Automatic Digital Refractometer RX-007a
ARX-007a:Automatic Digital Refractometer RX-007a Model RX-007α Cat.No. 3921 Measurement Range Brix 0.000 to 5.000% Refractive index (RI):1.330150 to 1.341500 Minimum Indication Brix 0.001% Refractive index (RI) 0.000001 Temperature 0.01°C Measurement Accuracy Brix±0.005% Refractive index (RI):±0.000010 (at 20°C) (under specified ambient temperature and constant temperature) Dimensions & Weight 37×26×14cm, 6.9kg (Main Unit only) Measurement Temperature 15.00 to 30.00°C Mode 2 types Power Supply AC100V to 240V, 50/60Hz Power consumption 480VA Output Terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-RX : Cat.No.3121 • Digital Printer DP-RD : Cat.No.3122 Parts • Printer paper (regular) for DP-RX : RE-8412 • Printer paper (long-term storage)for DP-RX : RE-8414 • Fan Filter Replacement : RE-58001
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-5000
ARX-5000:Automatic Digital Refractometer RX-5000 Model RX-5000 Cat.No. 3251 Measurement Range: Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.00 to 95.00% Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Measurement Accuracy/clear liquid Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature 5 to 60°C Repeatability Refractive index : ±0.00002 Brix : ±0.01% Power Supply: AC100 to 240V, 50/60Hz Dimensions & weight 37×20×12cm, 5.0kg (Main Unit only) Power consumption 75VA Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-62 : Cat.No.3018 • Volatile sample adapter for RX-5000 : RE-6560 • 10% Sucrose (±0.01%) : RE-111001 • 30% Sucrose (±0.01%) : RE-113001 • 50% Sucrose (±0.02%) : RE-115002
9,700.00 9700.0 USD
Sale
Automatic Digital Refractometer RX-5000a
ARX-5000a:Automatic Digital Refractometer RX-5000a Model RX-5000α Cat.No. 3261 Measurement Range: Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.00 to 100.00% ( 5 to 60°C ATC) Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature 5 to 60°C Repeatability Refractive index : ±0.00002 Brix : ±0.01% Power Supply to 240V, 50/60Hz Mode 3 types Dimensions & weight 37×26×14cm, 9.0kg (Main Unit only) Power consumption 480VA Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-RX : Cat.No.3121 • Digital Printer DP-RD : Cat.No.3122 • Digital printer DP-62α : Cat.No.3019 • Volatile sample adapter for RX-5000α : RE-56151 • Flow cell attachment :RE-56156 • 10% Sucrose (±0.01%) : RE-111001 • 30% Sucrose (±0.01%) : RE-113001 • 50% Sucrose (±0.02%) : RE-115002
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-5000a-Bev
ARX-5000a-Bev:Automatic Digital Refractometer RX-5000a-Bev Model RX-5000α-Bev Cat.No. 3271 Measurement Range Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.00 to 100.00% ( 5 to 60°C ATC) Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature 5 to 60°C Repeatability Refractive index : ±0.00002 Brix : ±0.01% Mode 3 types Power Supply AC100V to 240V, 50/60Hz Power consumption 480VA Dimensions & weight 37×26×14cm, 9.0kg (Main Unit only) Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital printer DP-RX : Cat.No.3121 • Digital printer DP-RD : Cat.No.3122 Parts • Cover plate : RE-56156 • Printer paper (regular) for DP-RX : RE-8412 • Printer paper (long-term storage)for DP-RX : RE-8414 • Fan Filter Replacement : RE-58001
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-5000i
ARX-5000i:Automatic Digital Refractometer RX-5000i Model RX-5000i Cat.No. 3276 Measurement Range: Refractive index (nD) : 1.32422 to 1.58000 Brix : 0.00 to 100.00% ( 5 to 75°C ATC) Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature ± 0.05°C Repeatability Refractive index (nD) : ±0.00002 Brix : ±0.01% Power Supply to 240V, 50/60Hz Weight 6.6kg (Main Unit only) Features include: -Internal Peltier Thermomodule; Measure at YOUR chosen temperature with NO waterbatch! -Touch Screen Interface; Simple, easy-to-use, and customizable -History Function; Automatically remembers the last 30 measurements -Programmable User Scale; Enter up to 98 of your own user scales for convenient, chart-free measurements -Password System; Maintain internal and external security -Simple, Fast Operation; Begin measuring in minutes of taking it out of the box -Versatile Connections; Hook up to a printer, or to MS Windows via USB -Compact design; Saves on important bench top space
11,300.00 11300.0 USD
Sale
Automatic Digital Refractometer RX-7000a
ARX-7000a:Automatic Digital Refractometer RX-7000a Model RX-7000α Cat.No. 3262 Measurement Range Refractive index (nD) 1.3250 to 1.7000 Brix 0.00 to 100.0% (ATC : 5 to 70°C) Minimum Indication 0.0001or 0.00001(by selection) Brix 0.1% or 0.01% (by selection) Temperature: 0.01°C Measurement Accuracy Refractive index (nD) ±0.0001 Brix ±0.1% Measurement Temperature 5 to 70°C Repeatability Refractive index : ±0.00005 Brix : ±0.02% Mode 3 types Power Supply AC100V to 240V, 50/60Hz Power consumption 480VA Dimensions & weight 37×26×14cm, 9.0kg (Main Unit only) Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-RX : Cat.No.3121 • Digital Printer DP-RD : Cat.No.3122 • Digital Printer DP-62α : Cat.No.3019 • Volatile sample adapter : RE-56152 • Flow cell attachment : RE-56155 • 10% Sucrose (±0.01%) : RE-111001 • 30% Sucrose (±0.01%) : RE-113001 • 50% Sucrose (±0.02%) : RE-115002 Parts • Cover plate : RE-6532 • Printer paper (regular) for DP-RX : RE-8412 • Printer paper (long-term storage)for DP-RX : RE-8414 • Fan Filter Replacement : RE-58001
11,000.00 11000.0 USD
Sale
Automatic Digital Refractometer RX-9000a
ARX-9000a:Automatic Digital Refractometer RX-9000a Model: RX-9000a Cat.No. 3263 Measurement Range Refractive index (nD) 1.32500 to 1.70000 Brix 0.00 to 100.00% (ATC : 5 to 70°C) Minimum Indication Refractive index (nD):0.00001 or 0.0001 (by selection) Brix 0.01% or 0.1% (by selection) Temperature: 0.01°C Measurement Accuracy Refractive index (nD) : ±0.00004 (nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C ) Refractive index (nD) : ±0.00010 (For ranges other than the above) Brix±0.03% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C Brix±0.05% (Brix 50.01 to 95.00% at Measurement Temperature 10.00 to 30.00°C Brix±0.10% (For ranges other than the above, with Sucrose solution by MODE1) Repeatability Refractive index (nD) : ±0.00002 (nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C ) Refractive index (nD) : ±0.00005 (For ranges other than the above) Brix±0.01% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C Brix±0.02% (For ranges other than the above, with Sucrose solution by MODE1) Measurement Temperature: 5 to 70°C Mode: 3 types Power Supply: AC100V to 240V, 50/60Hz Power consumption: 480VA Dimensions & weight: 37x26x14cm, 9.0kg (main unit only) Output terminals: Printer (for ATAGO digital printers and RS-232C)
14,500.00 14500.0 USD
Sale
Automatic Dispenser System
AD-300S; Automatic Dispenser System for DM-CE1
4,444.25 4444.25 USD
Sale
Automatic Piston Burette
APB-620; Automatic Piston Burette for Auto Titrator
5,152.00 5152.0 USD
Sale
Automatic Piston Burette
APB-610; Automatic Piston Burette for Auto Titrator
4,745.00 4745.0 USD
Sale
Automatic Piston Burette
APB-600-AT
4,067.00 4067.0 USD
Sale
Automatic Refractometer SMART-1
ASMART-1:Automatic Refractometer SMART-1 Model: SMART-1 Cat. No. 3150 Measurement Range: 1. Brix: 0.00 to 95.00% with ATC* 2. Inverted sugar concentration: 0.00 to 95.00% with ATC* 3. HFCS-55 (High Fructose Corn Syrup) : 0.00 to 95.00% with ATC* 4. HFCS-42 (High Fructose Corn Syrup) : 0.00 to 95.00% with ATC* *Automatic Temperature Compensation Minimum Indication: 1. Brix: 0.01% 2. Inverted sugar concentration : 0.01% 3. HFCS-55 (High Fructose Syrup) : 0.01% 4. HFCS-42 (High Fructose Syrup) : 0.01% Measurement Accuracy: 1. Brix: +- 0.05% (on measurement of sucrose) 2. Inverted sugar concentration : +- 0.05% 3. HFCS-55 (High Fructose Corn Syrup) : 0.05% 4. HFCS-42 (High Fructose Corn Syrup) : 0.05% Repeatability: 1. Brix: 0.01% 2. Inverted sugar concentration : 0.01% 3. HFCS-55 (High Fructose Corn Syrup) : 0.01% 4. HFCS-42 (High Fructose Corn Syrup) : 0.01% Measurement Temperature: 5 to 40degress C Power Consumption: 20VA Power Supply: AC100V to 240V, 50/60Hz Computer Communication: RS-232 International Protection Class: IP64 (excluding AC adapter) Dust tight/splash proof Output Terminals: Digital Printer DP-22 (optional) Communication system RS-232C Dimensions & Weight: 12 x27 x 9 cm, 2.0kg (main unit)
6,000.00 6000.0 USD
Sale
Automatic Titrator (with standard preamp)
KEM AT­-710B Automatic Potentiometric Titrator with Standard Preamp.

Specifications
­Type: Automatic Potentiometric Titrator

­Model: AT­710B

­Product configuration: AT­710 w/standard preamp, w/Magnetic stirrer
(combined pH electrode and temperature compensation electrode included)

­Detection range:
1) Potentiometric : ­2000mV to +2000mV
2) pH : ­20.000 to 20.00pH
3) Temperature : 0 to 100°C

­Titration mode: Auto Titration, Auto Intermit, Intermit, Stat
­Method: Standard method 20. (Max 2 methods can be linked)

­Kinds of titration: Potentiometric (acid/base, redox, precipitation), Photometric,
Polarization, Conductivity

­Titration form: Full titration (Auto EP detection), EP Stop, Level Stop

­Special application: Measurement of electrode potential (pH, potential), Acid
dissociation constant (pKa)

­Key operation: Sheet Key on the main unit

­Displays:
1) White LED­backlit LCD
2) English / Japanese / Mandarin Chinese /Korean / Russian / Spanish
3) 1­channel display

­Calculation: Concentration of content, statistics data processing (mean, SD
and RSD) and automatic averaging of blank and factor value

­Data Storage: 50 samples

­GLP conformance: Registration of operator / Record of check results / Record
of electrode calibration / Verification of burette capacity / Management of
conduction time

­Burette size: 20mL glass burette with brown cover (Standard) Optional burette
units: 10mL, 5mL, or 1mL

­Burette accuracy:
50mL burette(Auto dispenser) ± 0.5mL,
20mL burette ± 0.02mL reproducibility ± 0.01mL
10mL burette ± 0.015mL reproducibility ± 0.005mL
5mL burette ± 0.01mL reproducibility ± 0.003mL
1mL burette ± 0.005mL ; reproducibility ± 0.001mL

­External I/O:
RS­232 port x 2: for Dot matrix printer, Electronic balance, Data Capture
Software (SOFT­CAP)
SS­BUS × 1: for Multiple sample changer, APB
ELE. × 1: for Smart electrode
TEMP.COMP. × 1: an Input terminal for the temperature sensor to correct reagent
volume, sensor Pt100, temperature reading accuracy: ±0.5°C (burette 1 only)
USB × 1: for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot
switch, USB HUB, Android device

­Extensibility:
Automatic piston burette: Can control max 10 burette drives (Including two
built­in burette drives)
Multiple sample changer: CHA­700 series

­Ambient condition:

1) Temperature: 5 to 35°C
2) Humidity: 85%RH or below (no condensation)

­Power source: AC100 ­ 240V ±10% 50/60 Hz
­Power consumption: 20W

­Dimensions:
Titration unit: 141(W) × 296(D) × 367(H)mm
Printer: 106(W) × 180(D) × 88(H) mm

­Weight:
Titration unit: Approx. 4.0kg
Printer : Approx. 0.4kg

­Conformity standard: CE marking EMC: EN61326­1 LVD: EN61010­1 RE
Directive Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01
8,500.00 8500.0 USD
Sale
Automatick Piston Burette for Volumetri Titration
APB-600-KF
4,067.00 4067.0 USD
Sale
BJ Adaptor with seal
K550-5249: BJ Adaptor with seal
71.69 71.69 USD
Sale
BJP20 tube (L=1100)
K12-001-9400-48 (K439-5263):BJP20 tube (L=1100); Extra long delivery tube recommended for ease of reaching the sample changer
237.28 237.28 USD
Sale
BJP20 tube (black)/2000
K439-5264: BJP20 tube (black)/2000
179.22 179.22 USD
Sale
Balance Interface For Mka210 For Satorius As-210s
K10B-A21:Balance Interface For Mka210 For Satorius As-210s
577.50 577.5 USD
Sale
Base Unit w/USB output
HD35APU:HD35APU; Base unit with USB output; The base unit is the interface between the data loggers of the system, placed in the measurement sites, and the PC. It communicates wirelessly with the remote data loggers. The Delta OHM wireless data logging system allows to monitor many physical quantities in various application fields. Data loggers are available for the monitoring of: • Temperature • Relative humidity • Atmospheric pressure and differential pressure • Illuminance (lux) and UV irradiance • Carbon monoxide (CO) • Carbon dioxide (CO2) • Acceleration