Sale
Multi-Channel Heat Flow Meter
HFM-215 Multi-Channel Heat Flow Meter

-Connectable with all heat flow sensors
-3.5 inch color TFT LCD
-High capacity external memory: Internal memory (16MB) can store data of 55 hours when eight sensors of sensor constant A/B type are connected and sampling rate is set at one second. External memory media, compact flash or SD card (1 to 2 GB), enable continuous measurement.
-Equipped with Ethernet: Ethernet (10BASE-T/100BASE-TX) enables data collection through network
-Data communication: Equipped with e-mail transmitting, Web server, FTP server and FTP client functions. RS-485, RS-232C and USB communication devices can also be used.
-Dual power source: Both rechargeable battery and AC adapter can be used, making the HFM-215N compact and easy to carry. Batter life for continuous use is seven hours (may vary depending on conditions).
-Enhanced safety: Equipped with shock-resistant rubber cushions.
9,987.00 9987.0 USD
Sale
11 Position Sample Changer
CHA-700-11 : Automatic Titrator Multiple Sample Changer (11 sample)
9,900.00 9900.0 USD
Sale
Automatic Digital Refractometer RX-5000
ARX-5000:Automatic Digital Refractometer RX-5000 Model RX-5000 Cat.No. 3251 Measurement Range: Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.00 to 95.00% Minimum indication Refractive index (nD) : 0.00001 Brix : 0.01% Measurement Accuracy/clear liquid Refractive index (nD) : ±0.00004 Brix : ±0.03% Measurement Temperature 5 to 60°C Repeatability Refractive index : ±0.00002 Brix : ±0.01% Power Supply: AC100 to 240V, 50/60Hz Dimensions & weight 37×20×12cm, 5.0kg (Main Unit only) Power consumption 75VA Output terminals • Printer (for ATAGO digital printers) • RS-232C Optional • Digital Printer DP-62 : Cat.No.3018 • Volatile sample adapter for RX-5000 : RE-6560 • 10% Sucrose (±0.01%) : RE-111001 • 30% Sucrose (±0.01%) : RE-113001 • 50% Sucrose (±0.02%) : RE-115002
9,700.00 9700.0 USD
Sale
For Water Cooled Surface Heavy Duty
KTV-C: For Water Cooled Surface Heavy Duty
9,629.63 9629.630000000001 USD
Sale
For Water Cooled Surface Heavy Duty
KTV-B: For Water Cooled Surface Heavy Duty
9,629.63 9629.630000000001 USD
Sale
Refactometer
RA-600 Benchtop Refractometer

Specs:

-Measuring Method: Detection of Critical Angle of Optical Refraction
-Light Source: LED Na-D Line (589.3nm)
-Measuring Range: Refractive Index (nD)=1.3200 ~ 1.7000,
Brix=0.00 ~ 100.00%
-Accuracy *1:Refractive Index (nD)=±0.0001,Brix=±0.1%
-Repeatability *2:Refractive Index (nD)=±0.0001,Brix=±0.1%
-Resolution:Refractive Index (nD)=0.0001,Brix=0.10%
-Temperature Control:Peltier Thermostat 5 ~ 75°C *3
-Temperature Indication Resolution:0.1°C
-Minimum Amount of Sample
-Display:4.7-inch Backlit Colour LCD
-Operation:Touch Screen
-Security:Password Protection
-Data Storage: # of methods=100,Measurement results=up to 300, calibration record=up to 20,Check Record=up to 20, External Storage=USB Flash Drive
-Temperature Compensation: Brix=5.00 75.00 (Automatic compensation by preprogrammed conversion table.)
-Interfaces: LAN, USB1.1,RS-232
-Power Supply:AC 100~240 V, 50/60 Hz (AC adapter supplied with instrument.)
-Dimensions:191(W)×281(D)×161(H)mm
-Weight:5Kg
8,990.00 8990.0 USD
Sale
Evaporator (for Karl Fischer testing heavy Oil)
ADP-513 Karl Fischer Oil Evaporator

FEATURES:
-Digital temperature control
-Rotameter carrier gas flow control
-Built-in carrier gas drying system Operating temperature ambient up to 200°C Heated transfer tube
-Overheating protection
-Automatic cell evacuation system

SPECIFICATIONS:
Temperature Range: Room - 200°C
Heating method: Cartridge base heater
Ambient conditions: 5 - 35°C, less than 85% RH
Power: AC 200-240, 50/60Hz
Power Consumption: 400W
Dimensions: 320 x 210 x 330 mm
Weight: Approx. 6 kg
8,850.00 8850.0 USD
Sale
KEM Particle Analyzer
PCD-500
8,820.00 8820.0 USD
Sale
6 Position Sample Changer
CHA-700 : Automatic Titrator Multiple Sample Changer
8,500.00 8500.0 USD
Sale
Automatic Titrator (with standard preamp)
KEM AT­-710B Automatic Potentiometric Titrator with Standard Preamp.

Specifications
­Type: Automatic Potentiometric Titrator

­Model: AT­710B

­Product configuration: AT­710 w/standard preamp, w/Magnetic stirrer
(combined pH electrode and temperature compensation electrode included)

­Detection range:
1) Potentiometric : ­2000mV to +2000mV
2) pH : ­20.000 to 20.00pH
3) Temperature : 0 to 100°C

­Titration mode: Auto Titration, Auto Intermit, Intermit, Stat
­Method: Standard method 20. (Max 2 methods can be linked)

­Kinds of titration: Potentiometric (acid/base, redox, precipitation), Photometric,
Polarization, Conductivity

­Titration form: Full titration (Auto EP detection), EP Stop, Level Stop

­Special application: Measurement of electrode potential (pH, potential), Acid
dissociation constant (pKa)

­Key operation: Sheet Key on the main unit

­Displays:
1) White LED­backlit LCD
2) English / Japanese / Mandarin Chinese /Korean / Russian / Spanish
3) 1­channel display

­Calculation: Concentration of content, statistics data processing (mean, SD
and RSD) and automatic averaging of blank and factor value

­Data Storage: 50 samples

­GLP conformance: Registration of operator / Record of check results / Record
of electrode calibration / Verification of burette capacity / Management of
conduction time

­Burette size: 20mL glass burette with brown cover (Standard) Optional burette
units: 10mL, 5mL, or 1mL

­Burette accuracy:
50mL burette(Auto dispenser) ± 0.5mL,
20mL burette ± 0.02mL reproducibility ± 0.01mL
10mL burette ± 0.015mL reproducibility ± 0.005mL
5mL burette ± 0.01mL reproducibility ± 0.003mL
1mL burette ± 0.005mL ; reproducibility ± 0.001mL

­External I/O:
RS­232 port x 2: for Dot matrix printer, Electronic balance, Data Capture
Software (SOFT­CAP)
SS­BUS × 1: for Multiple sample changer, APB
ELE. × 1: for Smart electrode
TEMP.COMP. × 1: an Input terminal for the temperature sensor to correct reagent
volume, sensor Pt100, temperature reading accuracy: ±0.5°C (burette 1 only)
USB × 1: for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot
switch, USB HUB, Android device

­Extensibility:
Automatic piston burette: Can control max 10 burette drives (Including two
built­in burette drives)
Multiple sample changer: CHA­700 series

­Ambient condition:

1) Temperature: 5 to 35°C
2) Humidity: 85%RH or below (no condensation)

­Power source: AC100 ­ 240V ±10% 50/60 Hz
­Power consumption: 20W

­Dimensions:
Titration unit: 141(W) × 296(D) × 367(H)mm
Printer: 106(W) × 180(D) × 88(H) mm

­Weight:
Titration unit: Approx. 4.0kg
Printer : Approx. 0.4kg

­Conformity standard: CE marking EMC: EN61326­1 LVD: EN61010­1 RE
Directive Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01
8,500.00 8500.0 USD
Sale
Water activity meter /LabTouch-aw (basic)
Laboratory instrument WITH TOUCH-SCREEN for water activity measurement in foodstuff, drugs and cosmetic products.

-Measurement range aw : 0.06 ... 0.97aw, (non condensing)
-Measurement range temp. : 5 ... 45°C
-Sensor : with resistive-electrolytic measurement cell CM-2
-Instrument accuracy : +/- 0.005 aw, +/- 0.15K
-Communication : RS-232, USB 2x RS-485 for add. chambers SD card -> PC (NovaLog MC)

LabTouch-aw includes:
Dimensions : 200 x 300x 95 mm
Weight : 2.800 kg
 Measurement device LabTouch
 External universal power supply
 SD card 2GB Memory
 4 SAL-T: 33, 58, 75, 84% RH
 40 sample dishes ePW
 Spare pre-filters white (5 pcs)
 Tension ring
 Operating instructions
 Factory certificate of 7-point calibration, 11-33-58-75-84-90-97%
7,950.00 7950.0 USD
Sale
DA-100 Density/Specific Gravity Meter
KEM MODEL: DA-100 density/specific gravity meter
The built-in thermostatic control makes measurement stable in resulting values.
Thus, human error is eliminated in addition to easy operation and high precision.

>Measurement in a short period of time
>With built-in thermal control
>High precision thermal sensor is installed in measuring cell
>Concentration can be obtained by conversion.

Range: 0 - 3 g/cm3
Accuracy: ±0.001 g/cm3
Temperature: 15 - 40°C, 59 -°F
Display: 16 X 2 LCD with back light
Contents of display: Density, relative gravity, measurement temperature
Interface: RS232C single channel
7,900.00 7900.0 USD
Sale
Volumetric Karl Fischer Titrator
MKV-710B Volumetric Karl Fisher Titrator

Specifications:
-Type: Volumetric Karl Fischer Moisture Titrator

-Model: MKV-710B

-Product configuration: MKV-710+ Manual Solvent Change Unit.

-Measuring method: Karl Fischer Volumetric Titration

-Measuring range:
1. Water content: 0.1 to 500mgH2O (depends on KF reagent factor)
2. 10ppm to 100%H2O

-Burette precision: Volume: 10mL burette, Discharge precision: ±0.015mL repeatability, Repeatability: ±0.005mL

-Endpoint detection: By polarized potential level detected with a twin platinum electrode

-Titration form: Normal titration / Back titration (Option additional burette required)

-Required solvent: 30 to100mL (in S-type titration vessel)

-Methods: 20

-Key Operation: Sheet key on main unit

-Display:
1. White LED-backlit LCD
2. English / Japanese / Mandarin Chinese / Korean / Russian / Spanish
3. 1-channel display

-Calculation: Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and factor value

-Data storage: 100 samples

-GLP conformance: 􏰄registration of operator / 􏰅Record of check results/ Record of factor measurement / Management of conduction time

-External I/O:
1. RS232C port × 2 (for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP)
2. USB x 1 (for USB flash drive, thermal printer, Keyboard, Barcode reader, Foot switch, USB HUB, Android device)
3. SS-BUS x 1 (for APB)

-Extensibility
1. Automatic piston burette: Can control max 2 burette drives (including two built-in burette drives)

-Ambient Condition:
1. Temperature; 5 to 35°C
2. Humidity; 85%RH or below (no condensation)

-Power Source: AC100 - 240 ±10% 50/60 Hz

-Power Consumption: Main unit; Approx. 20W, Printer; Approx. 7W

-Dimensions:
1. Titration Unit; 141(W) × 292(D) × 367(H) mm (, not incl. tubing)
2. Stirrer; 107(W) × 206(D) × 322(H) mm (not incl. Solvent Change unit)
3. Solvent Change Unit; 240(W) × 140(D) × 400(H) mm (not incl. tubing)
4. Printer; 106(W)× 180(D) × 88(H) mm

-Weight:
1. Titration Unit = 4.0kg,
2. Stirrer = 2.0kg,
3. Solvent Change Unit = 0.6kg,
4. Printer = 0.4kg

-Conformity Standard: CE marking EMC : EN61326-1 LVD: EN61010-1 RE Directive Burette unit EBU FCC Part15 SubpartC FCC ID: 2ABSVEBU01
7,850.00 7850.0 USD
Sale
Coulometric Karl Fischer Titrator
MKC-710B Coulometric Karl Fisher Titrator
-Measuring Range; Water content / Bromine index: 10ug to 300mg
-Measurement cell; 2-Component or 1-Component
-Precision; Relative standard deviation : less than 0.3% (n=10) *Per KEM standard measurement conditions and standard liquids
-Display resolution; 0.1ug
-Methods; 20
-Data storage; 100 samples
-External I/O; -232C port × 2 (for printer, balance, software), USBx1 (for USB flash drive, printer, keyboard, barcode reader, foot switch, USB hub, Android device)
-Ambient Condition; (1) Temperature: 5 to 35°C (2): 85% H or below (no condensation)
-Power Source; AC100 - 240 ±10% 50/60 Hz
-Dimensions; 141(W ) × 292(D) × 244(H) mm
-Weight; Approx.3.0kg
-GLP Conformance; Registration of operator / Check performance with standard substance / reagent life control / Management of conduction time
-Conformity Standard; CE marking EMC: EN61326-1 L D: EN61010-1
7,850.00 7850.0 USD
Sale
Aquapal III Moisture Analyzer w/ Standard Glassware
Aquapal III Moisture Analyzer W/ Standard Glassware:
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved Manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm -% - ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
7,850.00 7850.0 USD
Sale
Aquapal III Moisture Analyzer w/ Single-reagent Glassware
Aquapal III Moisture Analyzer W/ Single Reagent Glassware: Coulometric Titrator Diaphramless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved Manufacturer. unit ready for operation, includes: - Built in printer with standard paper that backs up test with hard copy results. - Speed is 2 mg/minute - Test range from 1ppm to 100% - Sensitive to 0.1 ug - Calculations in Weight, volume or dilution - Automatic Drift Correction - Results printed in ppm ,% , ug - Standard RS232C output - Small lab foot print 14" x 8" - Portable (field Use) *Easy to use for non-technical operators - Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will printout automatically.
7,800.00 7800.0 USD
Sale
For Water Cooled Surface Heavy Duty
KEV-(L): For Water Cooled Surface Heavy Duty
7,648.71 7648.71 USD
Sale
UV-VIS Spectrophotometer (PC)
Model V-630 UV-VIS Spectrophotometer (PC)
7,465.00 7465.0 USD
Sale
Touch Panel Controller
MCU-610 Touch Panel Controller for Titrator
7,457.00 7457.0 USD
Sale
High Heat Flow/Embedding Heavy Duty
KTF-T-C: High Heat Flow/Embedding Heavy Duty
7,340.00 7340.0 USD